Ultra Violet Water Purification
Series 8300 |
 |
| Series 8300 |
|
| Horizontal Open Channel |
| 250 GPM to 2,000 GPM |
|
The series 8300 Ultraviolet
Disinfection product
line is design to simplify the process of selection and
installation, while providing user friendly operation and
maintenance. The Series 8300 incorporates state-of-the art
components to provide a simple, reliable product for
the control of waterborne microorganisms in wastewater.
Low pressure germicidal arc lamps are protected by quartz
sleeves and positioned horizontally, in an open channel,
parallel with the flow of effluent.
Reliability is our number one priority at Severn Trent Services.
Each 8300 Series system includes rugged stainless steel
UV lamp modules designed to be light weight and easy to
handle. Lamp modules may be mounted in a prefabricated
stainless steel channel or in a concrete channel built on
site. A compact, power supply center houses all of the UV
lamp power supplies and controls, providing easy access
for operation and maintenance. Interconnecting cables are
protected with rugged PVC insulation and terminate through
waterproof, multi-pin connectors. |
|
|
Features:
Easy Installation
Light Weight, Stainless Steel Lamp Modules
Quick Disconnect Power Cables
Efficient, Plug-In Electronic Power Supplies
UV Intensity Monitor
Designed for Outdoor Operation
Compact control panel bolts to a wall or railing near the channel
UV intensity monitor alerts operators when sleeve maintenance is required |
|
|
|
GENERAL |
|
|
Prefabricated Channel
304 stainless steel construction
Optional level control weir and inlet transition box
Built-in lamp module service rack |
|
|
UV Lamp Module
304 stainless steel construction
2 and 4 lamp configurations
Maximum weight including lamps & sleeves 20 pounds
Low pressure, slim line, UV lamp with single end connection
Test tube type protective quartz sleeves; PVC insulated, waterproof cable
and connector |
|
|
System Control Panel
Corrosion resistant stainless steel enclosure
Key lockable hinged door
Wall mounted within 25 feet of lamp modules |
|
|
Lamp Power Supplies
Plug-in circuit card design
Electronic, high frequency
Integral ground fault circuit interrupter
LED indication of ground fault; LED indication of lamp failure
Automatic shutdown on lamp failure |
|
|
Technical Data
UV Intensity Monitor
0-100% indication of germicidal UV intensity
Dual, fully adjustable alarm set points
Dual, form-C, alarm output contacts
240 Vac ±20%, 50/60 Hz, single phase, 3 Watts
4-20 mA output - 400 ohm maximum |
|
|