Marine Oil Content Monitors
OMD-2005
Specification
15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)
Range (measurement & indication)
0 - 30 ppm, Trend up to 50ppm
Range (IMO specification)
0 - 15 ppm (according IMO regulations)
Accuracy
better than IMO MEPC.107(49)
Electrical power supply
24V - 240V, AC or DC, automatic voltage adjustment
Electrical power consumption
< 15 VA
Sample
Oily water from separator outlet, 0,1 - 4 l/min
Sample temperature range
+1°C to +65°C
Sample connections
R 1/4" Female
Alarm 1 & 2 Set Points
1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation
1 - 540 sec
Alarm 2 operating delay for control
1 - 10 sec
Alarm contacts
2 independently adjustable switchover contacts
Alarm contact operation mode
De-energized in Alarm State
Alarm contact ratings
3A, 240V each
Alarm output
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
Display
Green Graphic Display
Ambient temperature
+1°C to +55°C
Class of protection
IP 65
Dimensions
360 x 240 x 100 mm (WxHxD)
Weight
7,3 kgs
(Note: The manufacturer reserves the right to change or amend specifications without notice.)
TRUSTWORTHY
◊
GLOBAL
◊
TECHSUPPLY
Better Business Bureau
Independent Report on PM&I
MANUFACTURING & DISTRIBUTION
SINCE 1985
SEARCH PM&I SITE
PM&I Company Causes
Society of Naval Architects
& Marine Engineers
PACIFIC MARINE & INDUSTRIAL
is a registered service mark of:
QUALITY PACIFIC MANUFACTURING, INC
Copyright © 1985-2012
All rights reserved.
Version 2.24