PACIFIC MARINE & INDUSTRIAL ®

Contact Information
Ph:(001)-510-233-2310 Toll Free:800-269-8750 Fx:(001)-510-233-2322
Web: www.pacificmarine.net Email: info@pacificmarine.net
Engineering Department Email:

Africa Asia & Middle East Europe S. America & Mexico US & Canada

TRUSTWORTHY GLOBAL TECHSUPPLY

Site Map

Marine Oil Content Monitors
OMD-2005

Specification  

15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)

Range (measurement & indication) 0 - 30 ppm, Trend up to 50ppm
Range (IMO specification) 0 - 15 ppm (according IMO regulations)
Accuracy better than IMO MEPC.107(49)
Electrical power supply 24V - 240V, AC or DC, automatic voltage adjustment
Electrical power consumption < 15 VA
Sample Oily water from separator outlet, 0,1 - 4 l/min
Sample temperature range +1°C  to +65°C
Sample connections R 1/4" Female
Alarm 1 & 2 Set Points 1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation 1 - 540 sec
Alarm 2 operating delay for control  1 - 10 sec
Alarm contacts 2 independently adjustable switchover contacts
Alarm contact operation mode De-energized in Alarm State
Alarm contact ratings 3A, 240V each
Alarm output 0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
Display Green Graphic Display
Ambient temperature +1°C to +55°C
Class of protection IP 65
Dimensions 360 x 240 x 100 mm (WxHxD)
Weight 7,3 kgs

(Note: The manufacturer reserves the right to change or amend specifications without notice.)

 

Receive our Technical News Letter:
Email:

[Home] [Up] [OMD-15] [OMD-17] [OMD-21] [OMD-2005]

Support these products that help people help themselves
Better Business Bureau

Better Business Bureau (BBB). Check up on us!

Independent Report
on PM&I
Site Map

Report Broken Links and Web Errors

Copyright © 1985-2007
Society of Naval Architects



& Marine Engineers
Pacific Marine & Industrial
is a
registered service mark of:

Quality Pacific Manufacturing, Inc.

P.O. Box 70520
Richmond, CA 94807
United States
 
All rights reserved.