OMD-17A with Auto-Clean
System
The OMD-17 Series is
designed for higher oil concentrations up to 100 ppm
oil-in-water. It is suited especially well for various
cooling water applications. This Monitor is type approved by
Germanischer Lloyd in accordance to the IMO-Resolution
MEPC.60 (33) and with increased oil concentrations.
Utilizing the latest "state of the art" in micro-processor
design and measuring technique, the benefits of the OMD-17
are:
Specification OMD-17 Series
|
Range:
|
0 - 99 ppm
|
|
Accuracy:
|
Better than
+/- 5 ppm insoluble Oil (with special calibration)
|
|
Degree of
Protection:
|
IP 65
|
|
Size
OMD-17:
|
175 x 190 x
220 mm (W x H x D)
|
|
Size OMD-17
A:
|
210 x 330 x
220 mm (W x H x D)
|
|
Sample
Temperature:
|
+1° to+ 90°
C
|
|
Alarm
Contact Rating:
|
Potential-free 1 pole change-over contacts, 3 A / 24
V
|
|
Alarm
Operating Points:
|
15 ppm
(Factory Set) adjustable from 1 - 99 ppm
|
|
Alarm 1 & 2
Operating Delay:
|
2 - 30 sec.
adjustable
|
|
Power
Supply:
|
24 Volt
AC/DC, other voltages on request
|
|
Output
Signal:
|
0 - 20 mA
or 4 - 20 mA, reversible Ri < 500 W
|
Models: OMD-17 -
without Auto-Clean System and
OMD-17A - with Auto-Clean System
|